(Based On 10 Reviews)

MECO Power and Harmonics Analyser Model PHA-5850 can Analyze, Measure, Monitor &Data Log values of Power Quality & Consumption (Energy).
Capable of analyzing IT standby power consumption to the maximum demand of factory. It comes with a user friendly application software that increases
the utility & performance of this instrument. The analyzer is ideal for an any Engineer / Inspector for carrying out Periodic Visits, Maintainance of Plant, Vigilance
checks, Surveys and Energy Audits for checking at Industrial and Consumers end.

Request Callback

Order In Bulk

Generate Quote

₹ 2,62,881.00

(GST inclusive price) i
  • Base Value: ₹ 222780.5
  • GST: (18) % ₹ 40100.5
  • Total Value ₹ 262881

₹2,62,881.00

( - 0% OFF )

Need Help ?

Our Client Care Managers Are On Call 24/7 To Answer Your Question.

Description

Key Features

  • Analysis of 3P4W, 3P3W, 1P2W, 1P3W Systems
  • Display of 35 Parameters in one screen (3P4W)
  • Programmable CT (1 to 600) and PT (1 to 3000) Ratios
  • RMS, PEAK Value & Crest Factor
  • True RMS value, Active Power, Apparent & Reactive Power ( KVA, KVAR)
  • Power Factor, Phase Angle ( ? ) & Energy (WH, KWH, KVARH, PFH)
  • Average / Maximum Demand (KW, MW, KVA, MVA) with Programmable Period
  • Display of 50 Harmonics in one Screen with Waveform with Peak value (1024 Sample / Period)
  • Analysis of total Harmonics Distortion (THD-F)
  • Capture 28 Transient Events with Programmable Threshold (%) (DIP, SWELL & OUTAGE)
  • Built-in timer & Calender for Data Logging
  • 512K Memory with Programmable interval (2 to 3000 seconds, 17000 records for 3P4W Systems)
  • Optical Isolated RS-232C ~ USB Interface
  • Calculated Unbalanced Current through Neutral line
  • Graphic Phasor Diagram
  • Facility to retrieve Power Data & Harmonics on Meter Screen
  • Software for easy download of Recorded Data & Transient events
  • Graphic Phasor Diagram
  • Facility to retrieve Power Data & Harmonics on Meter Screen
  • Software for easy download of Recorded Data & Transient events

 

What's in the box?

  • Voltage Test Leads
  • Alligator Clips (Voltage)
  • Carrying Bag
  • Batteries 1.5V
  • External DC Adaptor
  • Software CD
  • Users Manual
  • Software Manual
  • Optical USB Cable
  • Current Clamp

Rating & Reviews

4.5
(Based On 10 Reviews)

Rating

0

0

0

0

0

Product Specifications

General Specification
PowerEight x 1.5V AA Batteries
External DC InputPower supply adapter 12 Volts. DC
DisplayDot Matrix LCD (240x128) with backlight
LCD Update Rate1 time / second
Power Consumption140mA (approx.)
No. Of Samples1024 samples / period
Data Logging Files85
Max. File Capacity17474 records (3P4W, 3P3W)
26210 records (1P3W)
52420 records (1P2W)
4096 records (50 Harmonics / record)
2 to 3000 seconds for data logging
Sampling TimeOL
Operating Condition-10°C to 50°C < 85% RH 
Storage Condition -20°C to 60°C < 75% RH
Dimensions257 x 155 x 57 mm 
Weight1160 g (Batteries included)

 

Model : PHA-5850A (100A) (Overload Protection AC 200A) 
RangeResolutionAccuracy of Readings
0.04 - 1A 0.1mA / 1mA± 0.5% ± 0.05A
0.4 - 10A0.001A / 0.01A± 0.5% ± 0.05A
4 - 100A0.01A / 0.1A± 1.0% ± 0.5A

 

Model : PHA-5850B (1000A) (Overload Protection AC 2000A)
RangeResolutionAccuracy of Readings
10.00A0.001A / 0.01A 
5A - 100.0A0.01A / 0.1A± 0.5% ± 0.5A
50A - 1000.0A0.1A / 1A± 0.5% ± 5A

 

Model : PHA-5850C (3000A) (Overload Protection AC 3000A) 
RangeResolutionAccuracy of Readings
10.0 - 300.0A0.01A / 0.1A± 1% of range
300.0 - 3000A 0.1A / 1A

 

Model : PHA-5850D (1200A) (Overload Protection AC 1200A)
RangeResolutionAccuracy of Readings
6.0 - 120.0A0.01A / 0.1A± 1% of range
300.0 - 3000A 0.1A / 1A

 

Harmonic of AC Voltage in Percentage
RangeResolutionAccuracy of Readings
1 - 10th0.1%± 2%
11 - 20th± 4% of reading ± 2.0%
50 - 99th± 6% of reading ± 2.0%

 

Harmonic of AC Current in Percentage Model : PHA-5850A (100A)
RangeResolutionAccuracy of Readings
1 - 10th0.1%± 0.2% of reading ± 1%
11 - 20th ± 2% of reading ± 1%
21 - 50th (A range)± 5% of reading ± 1%
21 - 50th (mA range)± 10% of reading ± 1%
51 - 99th± 35% of reading ± 1%

 

Model : PHA-5850B (1000A) 
RangeResolutionAccuracy of Readings
1 - 20th0.1%±2%
21 - 49th± 4% of reading ± 2.0%
50 - 99th± 6% of reading ± 2.0% 

 

Model : PHA-5850C (3000A) & PHA-5850D (1200A)
RangeResolutionAccuracy of Readings
1 - 20th0.1%±2 %
21 - 49th± 6%
50 - 99th± 10%

 

Model : PHA-5850A (100A)
RangeResolutionAccuracy of Readings
5.0 - 999.9W0.1W± 1% ± 0.8W
1.000 - 9.999KW0.001KW± 1% ± 8W
10.00 - 99.99KW0.01KW± 1% ± 80W
100.0 - 999.9KW0.1KW± 1% ± 0.8KW
1000 - 9999KW1KW± 1% ± 8KW

 

Model : PHA-5850B (100A)
RangeResolutionAccuracy of Readings
5.0 - 999.9W0.1W± 1% ± 0.8W
1.000 - 9.999KW0.001KW± 1% ± 8W
10.00 - 99.99KW0.01KW± 1% ± 80W
100.0 - 999.9KW0.1KW± 1% ± 0.8KW
1000 - 9999KW1KW± 1% ± 8KW
0.000 - 9.999MW0.001MW± 1% ± 80KW

 

Model : PHA-5850C (3000A)
Model : PHA-5850D (1200A)
RangeResolutionAccuracy of Readings
10.0 - 999.9W0.1W>20V & >30A<20V or <30A
1.000 - 9.999KW0.001KW± 1% of range± 2% of range
10.00 - 99.99KW0.01KW
100.0 - 999.9KW0.1KW
1000 - 9999KW1KW

 

AC Voltage
(50Hz or 60H
RangeResolutionAccuracy of Readings
20.0V - 500.0V
(Phase to Neutral)
0.1V± 0.5% ± 5dgts

 

Power Factor (PF)
Model : PHA-5850A (100A) & PHA-5850B (1000A)
RangeResolutionAccuracy of Readings
0.00 - 1.000.1V± 0.04

 

Model : PHA-5850C (3000A) & PHA-5850D (1200A)
RangeResolutionAccuracy of Readings
0.000 - 1.0000.001>20V & >30A<20V or <30A