With its precision, reliability, and ease of use, the Fluke 3000 FC Wireless Multimeter has all the essential electrical and electronic troubleshooting features professional technicians need. It gives you true-RMS voltage and current measurements, 6000-count resolution, manual and automatic ranging, plus a frequency, capacitance, resistance, continuity and diode measurements.
Request Callback
Order In Bulk
Generate Quote
100% ORIGINAL Products
SECURE Payments
₹ 29,451.00
(GST inclusive price) i₹39,934.00
( - 26% OFF )
Description
Independently tested for safe use in CAT IV 600V/CAT III 1000 V environments, the Fluke 3000 FC DMM and Fluke Connect wireless modules put tools, not your body, near live electrical panels. Just de-energize the cabinet; open the panel while wearing PPE; and connect the remote modules—voltage modules, current clamps, flexible current loops or thermometers. Then read the results on the 3000 FC from a safe distance up to away. You can view the meter measurement, plus readings from up to three wireless modules all on the same screen. And by separating yourself from hazardous measurement situations you’ll reduce the risk of arc flash.
With Fluke Connect-enabled tools you can connect multiple remote modules in different parts of the system and view the interaction between remote test points on a single screen, in real time. Create and email reports right from the field, or download the data to a PC for further analysis. The Fluke 3000 FC connects to your smartphone through Bluetooth so you can send measurement data from the meter to your phone and share it with your team anytime, from anywhere.
What's in the box?
|
AC Voltage | ||
Range¹ / resolution | 600.0 mV / 0.1 mV 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V | |
Accuracy2 3 4 | 45 Hz to 500 Hz | 1.0% + 3 |
500 Hz to 1 kHz | 2.0% + 3 | |
1. AC voltage ranges are specified from 1% of range to 100% of range. 2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V. 3. For non-sinusoidial waveforms, add ± (2% of reading + 2% full scale) typical, for crest factor up to 3. 4. Do not exceed 107 V-Hz. | ||
DC Voltage, Continuity, Resistance, Diode Test and Capacitance | ||
mV | Range / resolution | 600.0 mV / 0.1 mV |
Accuracy | 0.09% + 2 | |
V | Range / resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V |
Accuracy | 0.09% + 2 0.15% + 2 | |
))) | Range / resolution | 600 Ω / 1 Ω |
Accuracy | Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer. | |
Ω | Range / resolution | 600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 60.00 kΩ / 0.1 kΩ 600.0 kΩ / 0.001 MΩ 50.00 MΩ / 0.01 MΩ |
Accuracy | 0.5% + 2 0.5% + 1 1.5% + 3 | |
Diode test | Range / resolution | 2.000 V / 0.001 V |
Accuracy | 1% + 2 | |
µF | Range / resolution | 1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF1 / 1 μF |
Accuracy | 1.2% + 2 10% typical | |
1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2. | ||
AC and DC Current | ||
mA AC (45 Hz to 1 kHz) | Range1 / resolution | 60.00 mA / 0.01 mA 400.0 mA3 / 0.1 mA |
Accuracy | 1.5% + 3 | |
mA DC2 | Range1 / resolution | 60.00 mA / 0.01 mA 400.0 mA3 / 0.1 mA |
Accuracy | 0.5% + 3 | |
1. All AC current ranges are specified from 5% of range to 100% of range. 2. Input burden voltage (typical): 400 mA input 2 mV/mA. 3. 400.0 mA accuracy specified up to 600 mA overload. | ||
Frequency | ||
Range / resolution | 99.99 Hz / 0.01 Hz 999.9 Hz / 0.1 Hz 9.999 kHz / 0.001 kHz 99.99 kHz / 0.01 kHz | |
Accuracy1 | 0.1% + 1 | |
1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps. | ||
Input Characteristics | ||
Overload protection | 1100 V RMS | |
Input impedance (nominal) | > 10 MΩ < 100 pF | |
Common mode rejection ratio (1 kΩ unbalance) | > 120 dB at DC, 50 Hz or 60 Hz | |
Normal mode rejection | > 60 dB at 50 Hz or 60 Hz | |
Overload protection | 1100 V RMS | |
Input impedance (nominal) | > 10 MΩ < 100 pF | |
Common mode rejection ratio (1 kΩ unbalance) | > 60 dB, DC to 60 Hz | |
Normal mode rejection | > 60 dB at 50 Hz or 60 Hz | |
Overload protection | 1100 V RMS | |
Input impedance (nominal) | > 10 MΩ < 100 pF | |
Common mode rejection ratio (1 kΩ unbalance) | > 120 dB at DC, 50 Hz or 60 Hz | |
Normal mode rejection | > 60 dB at 50 Hz or 60 Hz | |
Open Circuit Test Voltage | ||
Overload protection | 1100 V RMS | |
Input impedance (nominal) | < 2.7 V DC | |
Full scale voltage to 6 MΩ Full scale voltage 50 MΩ | < 0.7 V DC < 0.9 V DC | |
Typical short circuit current | < 350 mA | |
Overload protection | 1100 V RMS | |
Input impedance (nominal) | < 2.7 V DC | |
Full scale voltage to 6 MΩ Full scale voltage 50 MΩ | 2.000 V DC | |
Typical short circuit current | < 1.1 mA | |
mA Function | ||
Overload protection | Fused, 44/100 A, 1000 V FAST Fuse | |
Overload | 600 mA overload for 2 minutes maximum, 10 minutes rest minimum | |
MIN/MAX Recording Accuracy | ||
DC functions | ± 12 counts for changes > 350 mS in duration. | |
AC functions | ± 40 counts for changes > 900 mS in duration. | |
General Specifications | ||
Maximum voltage between any terminal and earth ground | 1000 V DC or AC RMS | |
Ω fuse protection from A inputs | 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only | |
Display (LCD) | Update rate | 4/sec |
Volts, amps, ohms | 6000 counts | |
Frequency | 10,000 counts | |
Capacitance | 1,000 counts | |
Battery type | Three AA Alkaline batteries, NEDA 15A IEC LR6 | |
Battery life | 250 hours minimum | |
RF communications | 2.4 GHZ ISM Band | |
RF communication range | Open air, unobstructed | Up to 20m |
Obstructed, sheetrock wall | Up to 6.5m | |
Obstructed, concrete wall, or steel electrical enclosure | Up to 3.5m | |
Temperature | Operating | -10°C to 50°C |
Storage | -40°C to 60°C | |
Temperature coefficient | 0.1 X (specified accuracy) / °C (< 18°C or > 28°C) | |
Relative humidity | 0% to 90% (0°C to 35°C) 0% to 75% (35°C to 40°C) 0% to 45% (40°C to 50°C) | |
Altitude | Operating | 2,000 m |
Storage | 12,000 m | |
Electromagnetic compatibility EMI, RFI, EMC, RF | EN 61326–1:2006, EN 61326–2–2:2006 ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008 FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID : FCC: T68–FDMMBLE IC: 6627A–FDMMBLE | |
Safety compliance | ANSI / ISA 61010–1 / (82.02.01): 3rd edition CAN / CSA-C22.2 No 61010-1-12: 3rd edition UL 61010–1: 3rd edition IEC / EN 61010–1:2010 | |
Certifications | CSA, FCC, CE | |
Ingress Protection (IP) rating | IP54 | |
Pollution Degree | 2 | |
Size (H x W x L) | 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in) | |
Weight | 340 g (12 oz) | |
Warranty | Three years | |
Not compatible with Fluke CNX test tools |