Item(s) Added To Your Bag
LUTRON AM-4224SD HOT WIRE ANEMOMETER
LUTRON AM-4224SD HOT WIRE ANEMOMETER
Lutron AM-4224SD is a versatile anemometer with telescopic probe and humidity sensor. It measures air flow, humidity, temperature, and dew point, offering data storage and communication options. Ideal for environmental testing, air balancing, and HVAC applications.
Request Callback
Order In Bulk
Generate Quote
100% ORIGINAL Products
SECURE Payments
₹ 15,600.00
(GST inclusive price) i₹15,600.00
( - 0% OFF )
Description
What's in the box?
|
Product Specifications
GENERAL SPECIFICATIONS | ||
Display | LCD size : 52 mm x 38 mm LCD with green backlight ( ON/OFF ). | |
Circuit | Custom one-chip of microprocessor LSI circuit. | |
Sensor Structure | Air velocity & Air flow | Tiny glass bead thermistor |
Air temperature | Thermistor | |
Humidity | Precision capacitance humidity sensor | |
Type K, Type J thermometer | Type K/J thermocouple probe. * Probes are optional. | |
Datalogger Sampling Time Setting range | Auto | 1 second to 3600 seconds @ Sampling time can set to 1 second,but memory data may loss |
Manual | Push the data logger button once will save data one time. @ Set the sampling time to 0 second. @ Manual mode, can also select the 1 to 99 position ( Location ) no | |
Memory Card | SD memory card. 1 GB to 16 GB. * It recommend use memory card ≦ 4 GB | |
Advanced setting | * Set clock time ( Year/Month/Date, Hour/Minute/ Second ) * Set sampling time * Auto power OFF management * Set beep Sound ON/OFF * Decimal point of SD card setting * SD memory card Format * Set thermometer type to Type K or Type J * Set temperature unit to ℃ or ℉ * Set air flow type ( CFM/USA, CMM/EURO ) * Set air flow area dimension | |
Temperature Compensation | Automatic temp. compensation for the Anemometer function and the type K/J thermometer. | |
Data Hold | Freeze the display reading. | |
Memory Recall | Maximum & Minimum value. | |
Sampling Time of Display | Approx. 1 second. | |
Data Output | RS 232/USB PC computer interface. * Connect the optional RS232 cable UPCB-02 will get the RS232 plug. * Connect the optional USB cable USB-01 will get the USB plug. | |
Operating Temperature | 0 to 50 ℃. | |
Operating Humidity | Less than 80% R.H. | |
Power Supply | * AAlkaline or heavy duty DC 1.5 V battery ( UM3, AA ) x 6 PCs, or equivalent. | |
* ADC 9V adapter input. ( AC/DC power adapter is optional ). | ||
Power Current | Normal operation ( w/o SD card save data and LCD Backlight is OFF) : Approx. DC 30 mA | |
When SD card save the data and LCD Backlight is OFF) : Approx. DC 50 mA. | ||
Weight | 347 g/ 0.76 LB. * Meter only | |
Dimension | Main instrument : 190 x 40 x 32 mm (7.5" x 1.6" x 1.3") | |
Main instrument : 182 x 73 x 47.5 mm ( 7.1 x 2.9 x 1.9 inch ) Telescope Probe : Round, 12 mm Dia x 280 mm ( min. length ). Round, 12 mm Dia x 940 mm ( max. length ). | ||
Optional Accessories | SD Card ( 2 G ) Type K thermocouple probe. AC to DC 9V adapter. USB cable, USB-01. RS232 cable, UPCB-02. Data acquisition software, SW-U801-WIN. Excel 'data acquisition software, SW-E802. |
ELECTRICAL SPECIFICATIONS (23± 5 ℃ )
Anemometer ( Air velocity ) | |||
Measurement | Range | Resolution | Accuracy |
m/S | 0.2 to 5.0 m/s | 0.01 m/s | ± ( 5% + a ) reading
or
± ( 1% + a ) full scale |
5.1 to 25.0 m/s | 0.1 m/s | ||
Km/h | 0.70 to 18.00 km/h | 0.01 Km/h | |
18.0 to 72.0 km/h | 0.1 Km/h | ||
FPM | 40-3940 ft/min | 1 Ft/min | |
mph | 0.50 to 11.20 mph | 0.01 mph | |
11.2 to 44.7 mph | 0.1 mph | ||
Knot | 0.40 to 9.70 knot | 0.01 Knot | |
9.7 to 38.8 knot | 0.1 Knot | ||
@ a = 0.1 m/s, 0.3 km/h, 0.2 mile/h, 0.2 knot, 20 ft/min | |||
Note : m/S (meters per second) mph ( miles per hour ) Km/h ( kilometers per hour ) Knot ( nautical miles per hour ) FPM ( feet per minute ) |
Air temperature | ||
Measuring Range | Resolution | Accuracy |
0 ℃ to 50 ℃ /32 ℉ to 122 ℉ | 0.1 ℃ /0.1 ℉ | ± 0.8 ℃ /1.5 ℉ |
Air flow | |||
Measurement | Range | Resolution | Area |
CMM ( m^3/min. ) CFM ( ft^3/min. ) | 0 to 45,000 CMM | 0.001 to 1 CMM | 0.001 to 30.000 m^2 |
0 to 1,589,200 CFM | 0.001 to 100 CFM | 0.01 to 322.93 ft^2 |
Humidity/ Temperature | |||
Range | Resolution | Accuracy | |
Humidity | 5 % to 95 % R.H. | 0.1 % R.H. | ≧ 70% RH ± (3% reading + 1% RH). < 70% RH : ± 3% RH. |
Temperature | 0 ℃ to 50 ℃ /32 ℉ to 122 ℉ | 0.1 degree | ± 0.8 ℃ . ± 1.5 ℉ . |
Dew point | ||
Range | Resolution | |
℃ | -25.3 ℃ to 48.9 ℃ | 0.1 ℃ |
℉ | -13.5 ℉ to 120.1 ℉ . | 0.1 ℉. |
Remark : * Dew Point display value is calculated from the Humidity/Temp. measurement automatically. * The Dew Point accuracy is sum accuracy value of Humidity & Temperature measurement. |
Wet bulb ( Humidity ) | ||
Range | Resolution | |
℃ | -21.6 ℃ to 50.0 ℃ | 0.1 ℃ |
℉ | -6.9 ℉ to 122.0 ℉ . | 0.1 ℉. |
Remark : * Wet bulb display value is calculated from the Humidity/Temp. measurement automatically. * The Welt bulb accuracy is sum accuracy value of Humidity & Temperature measurement. |