An ideal tool to test all machines and motors. The instrument can be used as a Digital Multimeter, an Insulation Tester, as well as a 4-wire Low Resistance Tester. This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic), Duty Cycle, Diode Test, Insulation Test and Continuity plus Thermocouple Temperature.
Request Callback
Order In Bulk
Generate Quote
100% ORIGINAL Products
SECURE Payments
₹ 33,399.00
(GST inclusive price) i₹44,955.00
( - 26% OFF )
Description
What's in the box?
|
General Specification | |
Enclosure | Double-moulded, waterproof |
Shock (Drop Test) | 3.2 feet (1m) |
Diode Test | Test current of 0.9mA maximum, open circuit voltage 2.8V DC typical |
Continuity Check | Audible signal will sound if the resistance is less than 50Ω (approx.), test current <0.35mA |
PEAK | Captures peaks >1ms |
Temperature Sensor | Requires type K thermocouple |
Input Impedance | >10MΩ VDC & >9MΩ VAC |
AC Response | True RMS |
AC True RMS | The term stands for “Root-Mean-Square,” which represents the method of calculation of the voltage or current value. Average responding multimeters are calibrated to read correctly only on sine waves and they will read inaccurately on non-sine wave or distorted signals. True RMS meters read accurately on either type of signal. |
ACV Bandwidth | 50Hz to 1000Hz |
Crest Factor | ≤3 at full scale up to 500V, decreasing linearly to ≤1.5 at 1000V |
Display | 50,000 Counts backlit liquid crystal with bar graph |
Overrange indication | “OL” is displayed |
Auto Power Off | 15 minutes (approximately) with disable feature |
Polarity | Automatic (no indication for positive); Minus (-) sign for negative |
Measurement Rate | 3 times per second, nominal |
Battery | 6 xAA NEDA 15A IEC LR6 |
Fuses | mA, µA ranges; 0.5A/1000V ceramic fast blow A range; 10A/1000V ceramic fast blow |
Operating Temperature | 41ºF to 104ºF (5ºC to 40ºC) |
Storage Temperature | -4°F to 14°F (-20ºC to 60ºC) |
Operating Humidity | Max 80% up to 87ºF (31ºC) decreasing linearly to 50% at 104ºF (40ºC) |
Storage Humidity | <80% |
Operating Altitude | 7000ft. (2000meters) maximum |
Safety | This meter is intended for installation use and protected by double insulation per EN61010-1 and IEC61010-1 2nd Edition (2001) to Category IV 600V and Category III 1000V; Pollution Degree 2. The meter also meets UL 61010-1, 2nd Edition (2004), CAN/CSA C22.2 No. 61010-1 2nd Edition (2004), and UL 61010B-2-031, 1st Edition (2003) |
DC Voltage | ||
Range | Resolution | Accuracy |
500mV | 0.01mV | ±(0.1% reading +4digits) |
5V | 0.0001V | |
50V | 0.001V | |
500mV | 0.01V | |
1000V | 0.1V |
AC Voltage (50 to1000Hz) | ||
Range | Resolution | Accuracy |
500mV | 0.01mV | ±(1.0% reading +5digits) |
5V | 0.0001V | ±(0.1% reading +4digits) |
50V | 0.001V | |
500mV | 0.01V | |
1000V | 0.1V |
DC Current | ||
Range | Resolution | Accuracy |
500µA | 0.01µA | ±(1.0% reading +3 digits) |
5000µA | 0.1µA | |
50mA | 0.001mA | |
500mA | 0.01mA | |
10A | 0.001A |
Resistance | ||
Range | Resolution | Accuracy |
500Ω | 0.01Ω | ±(1% reading + 9 digits) |
5kΩ | 0.0001kΩ | ±(1% reading +4 digits) |
50kΩ | 0.001kΩ | |
500kΩ | 0.01kΩ | |
5MΩ | 0.001MΩ | ±(2.0% reading +9 digits) |
50MΩ | 0.001MΩ | ±(3.0% reading +9 digits) |
AC Current | ||
Range | Resolution | Accuracy |
500µA | 0.01µA | ±(1.5% reading + 3digits) (50 to1000Hz) |
5000µA | 0.1µA | |
50mA | 0.001mA | |
500mA | 0.01mA | |
10A | 0.001A |
Capacitance | ||
Range | Resolution | Accuracy |
500nF | 0.01nF | ±(3.5% reading + 40 digits) |
5µF | 0.0001µF | ±(3.5% reading +9digits) |
50µF | 0.001µF | |
500µF | 0.01µF | |
5.000mF | 0.0001mF | ±(5% reading +9digits) |
Frequency (electronic) | ||
Range | Resolution | Accuracy |
50Hz | 0.001Hz | ±(0.3% reading +2 digits) |
500Hz | 0.01Hz | |
5kHz | 0.0001kHz | |
50kHz | 0.001kHz | |
500kHz | 0.01kHz | |
5MHz | 0.0001MHz | |
50MHz | 0.001MHz |
Frequency (electrical) | ||
Range | Resolution | Accuracy |
40.00Hz-10KHz | 0.01Hz - 0.001KHz | ±(0.5% reading) |
Meg Ohms | ||||
Terminal Voltage | Range | Resolution | Accuracy | Test Current |
50V (0%~+20%) | 0.050~5.000 MΩ | 0.001MΩ | +(2%+10) | 1mA @load 50kΩ |
5.000~50.00 MΩ | 0.01MΩ | +(3%+10) | ||
50.00~500.0 MΩ | 0.1MΩ | +(4%+5) | ||
500~2000 MΩ | 1MΩ | +(5%+5) | ||
100V (0%~+20%) | 0.100~5.000 MΩ | 0.001MΩ | +(2%+10) | 1mA @load 100kΩ |
5.000~50.00 MΩ | 0.01MΩ | +(3%+10) | ||
50.00~500.0 MΩ | 0.1MΩ | +(4%+5) | ||
500~5000 MΩ | 1MΩ | +(5%+5) | ||
250V (0%~+10%) | 0.250~5.000 MΩ | 0.001MΩ | +(2%+10) | 1mA @load 250kΩ |
5.000~50.00 MΩ | 0.01MΩ | +(3%+10) | ||
50.00~500.0 MΩ | 0.1MΩ | +(4%+5) | ||
500~5000 MΩ | 1MΩ | +(5%+5) | ||
500V (0%~+10%) | 0.500~5.000 MΩ | 0.001MΩ | +(2%+10) | 1mA @load 500kΩ |
5.000~50.00 MΩ | 0.01MΩ | +(3%+10) | ||
50.00~500.0 MΩ | 0.1MΩ | +(3%+5) | ||
500~5000 MΩ | 1MΩ | +(4%+5) | ||
1000V (0%~+10%) | 1.000~5.000 MΩ | 0.001MΩ | +(2%+10) | 1mA @load 1MΩ |
5.000~50.00 MΩ | 0.01MΩ | +(3%+10) | ||
50.00~500.0 MΩ | 0.1MΩ | +(4%+5) | ||
500~5000 MΩ | 1MΩ | +(5%+5) |
Low Resistance Measurement | ||||
Range | Resolution | Accuracy | Test Voltage | Overload Protection |
0.000~5.000Ω | 0.001Ω | +(1.5%+30) | 5.0+1V | 250V RMS |
5.00~50.00Ω | 0.01Ω | +(2.0%+5) | ||
50.0~500.0Ω | 0.1Ω | +(2.5%+5) | ||
500 ~2000Ω | 1Ω | +(3.0%+5) |