Item(s) Added To Your Bag
Metravi PRO 589 Digital TRMS Multimeter
Metravi PRO 589 Digital TRMS Multimeter
Professional True RMS Industrial Digital Multimeter and TFT color LCD display, providing fast A/D converting sampling time, high accuracy, built-in data logging, and Trend Capture features. AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic), Duty Cycle, Diode Test, Insulation Test, and Continuity plus Thermocouple Temperature. It can store and recall data. It features a waterproof, rugged design for heavy duty use.
Request Callback
Order In Bulk
Generate Quote
100% ORIGINAL PRODUCTS
SECURE PAYMENTS
1 YEAR WARRANTY
AUTHORIZED DISTRIBUTOR
B2B INVOICES
₹ 22,799.00
(GST inclusive price) i₹30,679.00
( - 26% OFF )
Description
What's in the box?
|
Polarity : Automatic (no indication for positive); Minus (-) sign for negative
Measurement Rate : 20 times per second, nominal
Low Battery Indication : “ ” is displayed if battery voltage drops below operating voltage
Battery : 7.4 Volts Rechargeable Lithium Battery
Fuses : mA, mA ranges; 0.8A/1000V ceramic fast blow A
range; 10A/1000V ceramic fast blow
Operating Temperature : 5°C to 40°C (41°F to 104°F)
Storage Temperature : -20°C to 60°C (-4°F to 140°F)
Operating Humidity : Max 80% up to 31°C (87°F)” decreasing linearly to 50% at 40°C (104°F)
Storage Humidity : 50% at 40°C (104°F)
Operating Altitude : <80% 7000ft. (2000meters) maximum
IP Rating : 67) (IP Proof Dust And Proof Water
AC Voltage
Range | Resolution | 50/60Hz | <1KHz | <5KHz | ≤100KHz [1] |
500mV | 0.01mV | ±0.5% | ±1.5% | ±3.0% | ±5.5% |
5V | 0.0001V | +5 | +5 | +5 | +20 |
50V | 0.001V |
|
|
|
|
500V | 0.01V | ±1.5% | ±3.5% | Unspecifie | |
|
|
| +10 | +10 | |
1000V | 0.1V |
|
| Unspecifie | Unspecifie |
[1] Upper10% of range,sine wave. Low Pass Filter : RANG 1000V 50/60Hz (+-1%+10) 40-400Hz (+-3%+10) > 3KHz (-3dB) |
DC Voltage
RANGE | RESOLUTION | ACCURACY |
500mV[1] | 0.01mV | (0.1% + 5digits) |
5V | 0.0001V | (0.05% + 5digits) |
50V | 0.001V | (0.05% + 5digits) |
500V | 0.01V | (0.05% + 5digits) |
1000V | 0.1V | (0.1% + 5) |
[1] Whenusing the relative mode (REL Q ) to compensate for offsets. |
(AC + DC)
Range | Resolution | <1KHZ | <5KHZ |
5V | 0.0001V | (1.5% + 20) | (3.0% + 20) |
50V | 0.001V | ||
500V | 0.01V | ||
1000V | 0.1V |
Resistance
RANGE | RESOLUTION | ACCURACY |
500W [1] | 0.01W | 0.20% + 10 |
5KW | 0.0001kW | 0.20% + 5 |
50KW | 0.001kW | 0.20% + 5 |
500KW | 0.01kW | 0.50% + 5 |
5MW | 0.0001MW | 0.50% + 5 |
50MW | 0.001MW | 2.0% +10 |
[1] Whenusing the relative mode (REL Q ) to compensate for offsets. |
Temp(type-K)
RANGE | RESOLUTION | ACCURACY |
-200 to 1350°C |
0.1C | ±(1.0% reading +3.0°C) ±(1.0% reading +5.4°F) (probe accuracy not included) |
1. Doesnot include errorof the thermocouple probe. | ||
2. Accuracy specification assumes ambient temperature stable to ±1°C | ||
3. Usea long time,reading will increase 2°C | ||
4. <-50°C Temp Rang accuracy ± (3%+5°C) |
DC Current
RANGE | RESOLUTION | ACCURACY |
500mA | 0.01mA | ±0.2%+5 |
5000mA | 0.1mA | ±0.2%+5 |
50mA | 0.001mA | ±0.2%+5 |
500mA | 0.01mA | ±0.3%+8 |
10A | 0.001A | ±0.5%+8 |
AC Current
RANGE | RESOLUTION | ACCURACY | |
|
| <1KHZ | <5KHZ |
500mA | 0.01mA | ±(0.8% +5) | ±(3% +5) |
5000mA | 0.1mA | ||
50mA | 0.001mA | ||
500mA | 0.01mA | ||
10A | 0.001A | ||
(20A : 30 sec max withreduced accuracy) | |||
All AC currentranges are specified from 5% of range to 100% of range |
Capacitance
RANGE | RESOLUTION | ACCURACY |
5nF [1] | 0.001nF | ±(1.5% +20) |
50nF | 0.01nF | ±(1.5% +8) |
500nF | 0.1nF | ±(1.0% +8) |
5mF | 0.001mF | ±(1.5% +8) |
50mF | 0.01mF | ±(1.0% +8) |
500mF | 0.1mF | ±(1.5% +8) |
10mF | 0.01mF | ±(2.5% +20) |
[1] With a film capacitor or better, usingrelative mode (REL△ ) to zero residual. |
Frequency (electronic)
RANGE | RESOLUTION | ACCURACY |
50Hz | 0.001Hz | ±(0.01% +5) |
500Hz | 0.01Hz | ±(0.01% +5) |
5kHz | 0.0001kHz | ±(0.01% +5) |
50kHz | 0.001kHz | ±(0.01% +5) |
500kHz | 0.01kHz | ±(0.01% +5) |
5MHz | 0.0001MHz | ±(0.01% +5) |
10MHz | 0.001MHz | Unspecified |
Sensitivity : 2V rmsmin. @ 20% to 80% dutycycle and <100kHz; 5V rms min@20% to 80% duty cycleand >100kHz. |
Frequency (electrical)
RANGE | RESOLUTION | ACCURACY |
10.00Hz - 10KHz | 0.01Hz - 0.001KHz | ±(0.5% reading) |
Sensitivity : 2V rms |
Duty Cycle
RANGE | RESOLUTION | ACCURACY |
0.1 to 99.90% | 0.01% | ±(1.2% +2 reading) |
Pulse width : 100ms - 100ms,Frequency : 5Hzto 150kHz |
Similar Products
Request Callback
We will get in touch with you
More From Brands
Enter your requirement details!
We will get in touch with you.