Item(s) Added To Your Bag

METRAVI 23S-TRMS Digital TRMS Multimeter

Click To Zoom

METRAVI 23S-TRMS Digital TRMS Multimeter

METRAVI 23S-TRMS Digital TRMS Multimeter

(Based On 10 Reviews)

4-1/2 Digits 19,999 Counts, T-RMS, Backlit LCD, NCV, Data Hold, Peak Hold, Relative, Auto Power Off, Dual Display to show Voltage & Current with Frequency on the same screen, AC/DC Voltage, AC/ DC Current 10A, Resistance, Capacitance, Temperature, Frequency, Diode & Continuity Test both Audio and Visual.

Request Callback

Order In Bulk

Generate Quote

100% ORIGINAL PRODUCTS
Your source for authentic goods. No fakes, just the real deal.

100% ORIGINAL PRODUCTS

SECURE PAYMENTS
Risk-free Transactions

SECURE PAYMENTS

LIFETIME WARRANTY
Terms & Conditions apply.

LIFETIME WARRANTY

B2B INVOICES
Enter your GSTIN at the time of checkout for claiming GST input.

B2B INVOICES

₹ 4,062.00

(GST inclusive price) i
  • Base Value: ₹ 3442.4
  • GST: (18) % ₹ 619.6
  • Total Value ₹ 4062

₹5,468.00

( - 26% OFF )

Need Help ?

Our Client Care Managers Are On Call 24/7 To Answer Your Question.

Description

Key Features

  • Display: 20,000 Counts BacklitDual LCD display
  • T-RMSMeasurements of Voltageand Current
  • DataHold, Peak Hold
  • Relative Measurement
  • NonContact Voltage Detection
  • AutoPower Off
  • Maximum display: 20000 (4-1/2)digits automatic polaritydisplay;
  • Measurement method: double integralA / D conversion;
  • Sampling rate: about 3 times per second;
  • Over-range display: the highestbit was “OL”;
  • Low voltagedisplay: “              ”
  • Working environment: (0 ~ 40) °C, relative humidity<8 0%;
  • Power: 9V (NEDA1604 / 6F22);
  • Size:184 *90 *46mm (length ,widthand height);
  • Weight: about 320g (including 9V battery);

 

What's in the box?

  • METRAVI 23S-TRMS Digital TRMS Multimeter
  • A manual
  • Test Certificate
  • a pair of test leads
  • K-type thermocouple.

Rating & Reviews

4.5
(Based On 10 Reviews)

Rating

0

0

0

0

0
Review Image

Product Specifications

DC Voltage (DCV)

RangeAccuracyResolution
200mV(0.05%+5)0.01mV
2V0.0001V
20V0.001V
200V0.01V
1000V(0.08%+10)0.1V
Input impedance: 10M Ω 
Overload protection: 200mV range of 550V DC or AC
peak; the remaining 1000V DC or 750V AC peak.

AC Voltage (T-RMS)

RangeAccuracyResolution
200mV(0.06%+25)0.01mV
2V0.0001V
20V0.001V
200V0.01V
750V(0.8%+15)0.1V
Input impedance: 10MΩ; standard sine wave and
triangular wave frequency response of 40Hz-1kHz; other
waveform frequency response 40Hz-200Hz; 

DC Current

RangeAccuracyResolution
200uA(0.5%+4)0.01uA
2000uA0.000mA
20mA(0.8%+6)0.001A
200mA0.01A
10A(1.0%+6)0.1A
Maximum measurement pressure drop: 200mV;
Maximum input current of 10A
Overload protection: 200mA/250Vglass instant
fuse, 10A / 250V ceramic instant fuse
(10A continuous measurement <10 seconds) 

AC Current (T-RMS)

RangeAccuracyResolution
200uA(0.5%+4)0.01uA
2000uA0.000mA
20mA(0.8%+6)0.001A
200mA0.01A
10A(1.0%+6)0.1A

Maximum measurement pressure drop: 200mV;
Maximum input current of 10A
Overload protection: 200mA/250Vglass instant
fuse, 10A / 250V ceramic instant fuse
(10A continuous measurement <10 seconds) 

Frequency response: sine wave and triangular wave
for the 40Hz-1Kz, other waveform 40Hz-200Hz;
Show: True RMS;

Resistance

RangeAccuracyResolution
200Ω(0.5%+4)0.01Ω
2kΩ0.1Ω
20kΩ(0.8%+6)
200kΩ10Ω
2MΩ (1.0%+6)100Ω
20MΩ  1kΩ
Open circuit voltage: below 3V; Overload
protection: 550VDC or AC peak value;
NCV Testing: When chosing this function the
instrument detects presence of electro-magnetic
field, the buzzer sound will start and would increase
with the intensity of electro-magnetic field.

Capacitance

RangeAccuracyResolution
20nF(3.0%+20)1pF
200nF10pF
2uF0.1nF
20uF1nF
200uF(5.0%+10)10nF
2000uF100nF
Overload protection: 550V DC or AC peak value.

Frequency

RangeAccuracyResolution
10Hz(0.01%+3)0.001 Hz
100 Hz0.01 Hz
1k Hz0.1 Hz
10k Hz1 Hz
100k Hz1 0Hz
1M Hz/20M Hz(0.8%+15)100Hz/1k Hz
Input sensitivity: 1.5V RMS;
Overload protection : 550V DC or AC peak value
(not over 10second)

Temperature

RangeAccuracyResolution
10Hz(0.01%+3)0.001 Hz
100 Hz0.01 Hz
1k Hz0.1 Hz
10k Hz1 Hz
100k Hz1 0Hz
1M Hz/20M Hz(0.8%+15)100Hz/1k Hz

Diode and Continuity Testing

Range

Display value

Testing condition

 

Positive diode voltage drop

PositiveDC currenabout1mA, Open circuit voltage about 3V,

 

Buzzer withlonbuzzing Sound The resistance of 2 testingpoint below (50±2 0)Ω

 

Opencircuitvoltagabout 3V Press “SELECT” can convert the 2 function

Overload protection: 550V DC or AC peak value.