Item(s) Added To Your Bag

Metravi TTRS-100 Transformer Turns Ratio Set

Click To Zoom

Metravi TTRS-100 Transformer Turns Ratio Set

Metravi TTRS-100 Transformer Turns Ratio Set

(Based On 10 Reviews)

Request Callback

Order In Bulk

Generate Quote

₹ 17,790.00

(GST inclusive price) i
  • Base Value: ₹ 15076.3
  • GST: (18) % ₹ 2713.7
  • Total Value ₹ 17790

₹1,79,550.00

( - 0% OFF )

Need Help ?

Our Client Care Managers Are On Call 24/7 To Answer Your Question.

Description

Key Features

  • Wide measuring range
  • Better resolution
  • Measures percentage ratio & phase error directly
  • Advanced design using integrated circuits
  • Efficient shielding technique
  • Compact in size
  • Phase sensitive null detector
  • Checks polarity

 

What's in the box?

  • Transformer Turns Ratio Set

Rating & Reviews

4.5
(Based On 10 Reviews)

Rating

0

0

0

0

0

Product Specifications

Technical Specification
Measuring RangeTransformer ratio measurements are carried out in 10 ranges Arranged in a 1, 2, 5,10 sequence. For TTRS-100 the measuring span has a range of ratios from 0.800 to 2021. The ratio resolution is 0.01%. In this model phase deviation measurements are carried out in two ranges. Namely ±5.5 cent-radians (1CR=34minutes)
Accuracy±0.1% of reading.
Course balancingBy selector switches provided on panel.
Fine BalancingBy vernier potentiometer provided on panel.
Excitationmagnitude of excitation voltage applied to the transformer under test. This meter provides 1.2V, 12V & 120 volts excitation voltage. This voltage is isolated from the mains supply for operator's safety. It is preferable to take readings on 120volts whenever possible.
Direct ratio error measurement range± 0.1% of the range with a resolution of 0.02%
Direct ratio error
measurement Accuracy
± 0.25% of the reading.
Null DetectorThe solid state, synchronous and phase sensitive null detector with Adjustable gain control provides high sensitivity for both ratio and phase balance.
ProtectionOver load / Short circuit & H.T. /L.T. reversal
Polarity checkProvided.
Power supply Input230 volts ± 10% single phase, 50Hz. A.C.
ConstructionThe ratio meter is housed in a sturdy metal case and is built with the operator's safety and convenience in view. All functionally similar controls are grouped together for ease of operation. Connections between the transformer under test and the instrument are made at clearly identified binding posts. All ratio dials and ratio multiplier selector switch and dial are similarly grouped. Null detector sensitivity control is adjacent to the null detector.
The zero center null indicators are coordinated with the ratio and phase dials such that the rotation of dials in a direction opposite to the deflection of the null indicator brings closer to balance.

Rating & Reviews

4.5
(Based On 10 Reviews)

Rating

0

0

0

0

0