Item(s) Added To Your Bag
MECO 3510 PHW Power Meter
MECO 3510 PHW Power Meter
Request Callback
Order In Bulk
Generate Quote
₹ 17,820.00
(GST inclusive price) i₹17,820.00
( - 0% OFF )
Description
What's in the box?
|
General Specification | |
Numerical Dual Display | 4 Digit 9999 Count LCD |
Low Battery Indication | is displayed |
Power | 9V Battery x 1 |
Sampling Rate | 2.5 times/sec. (Digital Display) 1 times/6 sec. (on KW, KVA) |
Operating Temperature and Humidity | 0 C to 50 C (32 F to 122 F) RH < 80% non-condensing |
Storage Temperature and Humidity | -10 C to 60 C (14 F to 140 F) RH < 70% non-condensing |
Dimensions | 247 x 90 x 40mm |
Weight | 425gms Including Battery (approx.) |
Jaw Opening | Cable Dia 43mm (max.) Bus Bar 16mm x 65mm |
Auto Power off Time | Approx. 30 minutes |
Temperature Coefficient | 0.1 x (specified accuracy) / C0 (<18 or>28 C, <64 or >82 F) |
Electrical Specification | ||||
DC Voltage | ||||
Range | Resolution | Accuracy ±(%rdg+dgts) | Sensitivity | Overload Protection |
999.9mV | 0.1mV | ±(1% + 30) | 2.0mV | 600V |
9.999V | 0.001V | 0.020V | ||
99.99V | 0.01V | 0.20V | ||
600.0V | 0.1V | 2V | ||
Input Impedance : 3MV |
Resistance (Continuity < 40 on the 999.9 range) | |||
Range | Resolution | Accuracy ±(%rdg+dgts) | Overload Protection |
999.9 | 0.1 V V | ±(1% + 10) | 500V DC or AC rms for 1 min. |
9.999K | 0.001K | ||
99.99K | 0.01K | ||
999.9K | 0.1K |
M (Auto Ranging) | |||
Range | Resolution | Accuracy ±(%rdg+dgts) | Overload Protection |
9.999M | 0.001M | ±(5% + 10) | 500V DC or AC rms for 1 min. |
99.99M | 0.01M |
Capacitance | |||
Range | Resolution | Accuracy ±(%rdg+dgts) | Overload Protection |
10.000µF | 0.001µF | ±(3.0% + 5) | 500V DC or AC rms for 1 min. |
100.00µF | 0.01µF | ±(1.5% + 5) | |
1000.0µF | 0.1µF | ||
7000µF | 1µF | ±(2.5% + 15) |
Diode (Continuity < 40mV) | |||
Range | Resolution | Accuracy ±(%rdg+dgts) | Overload Protection |
2.000V | 0.001V | ±(2% + 1) | 500V DC or AC rms for 1 min. |
Temperature (K-Type Thermocouple) | |||
Range | Resolution | Accuracy ±(%rdg+dgts) | Overload Protection |
-50°C to 900°C | 0.1°C | ±(.2% + 4°C) | 30VAC or 60VDC |
-58°F to 1000°F | 0.1°F | ±(.2% + 6°F) |
1 /3 TRUE Power (KW) : (PF lag 1.000~0.000~lead 1.000 or f f 00.00°~360.0°) (1 hp=0.7457KW) | |||
Range | Resolution | Accuracy ±(%rdg+dgts) | Overload Protection |
99.99KW | 0.01KW | ±(5% + 30) (50, 60Hz) | 600VAC/ 1000AAC |
600.0KW | 0.1KW |
1 /3 HP (1HP=745.7W) : (PF lag 1.000~0.000~lead 1.000 or f f 00.00°~360.0°) | |||
Range | Resolution | Accuracy ±(%rdg+dgts) | Overload Protection |
99.99HP | 0.01 HP | ±(5% + 30) (50, 60Hz) | 600VAC/ 1000AAC |
800.0HP | 0.1 HP |
1 /3 Apparent Power (KVA) | |||
Range | Resolution | Accuracy ±(%rdg+dgts) | Overload Protection |
99.99KVA | 0.01 KVA | ±(2.5% + 30) | 600VAC/ 1000AAC |
600.0KVA | 0.1 KVA |
1 /3 Reactive Power (KVAR) : (PF lag 1.000~0.000~lead 1.000 or f f 00.00°~360.0° | |||
Range | Resolution | Accuracy ±(%rdg+dgts) | Overload Protection |
99.99KVAR | 0.01KVAR | ±(5% + 50dgts | 600VAC/ 1000AAC |
600.0KVAR | 0.1KVAR | (50, 60Hz |
3 Phase Sequence Indication | ||
Range | Frequency Response | Overload Protection |
80V to 480V | (50Hz / 60Hz) | 600V |
ACA Inrush Current | ||||
Range | Resolution | Sensitivity | Measurement Time | Overload Protection |
99.99A | 0.01A | >5A | 100ms | 1000A AC |
999.9A | 0.1A | >50A |
1 /3 PF & Phase Angle (50Hz, 60Hz) | |||
Range | Resolution | Accuracy | Sensitivity |
00.00°~99.99° | 0.01° | ± 6.0° | ACV>100V, ACA>10A |
100.0°~360.0° | 0.1° | ||
lag 1.000~0.000~ lead 1.000 | 0.001 |
Frequency | |||
Range | Resolution | Accuracy ±(%rdg+dgts) | Sensitivity |
40.00Hz~999.9Hz | 0.01Hz/0.1Hz | ±(0.5% + 2) | ACV>1.2V, ACA>6A |
AC Current (50Hz to 400Hz) : TRMS Range Resolution Accuracy | ||||
Range | Resolution | Accuracy ±(%rdg+dgts) | Sensitivity | Overload Protection |
99.99A | 0.01A | ±(2% + 30) (50,60Hz) | 0.10A | 1000A |
999.9A | 0.1A | ±(4% + 30) (40-400Hz) | 1.0A |
m m A : DC + AC TRMS (Burden Voltage : 5mV/ A) (50Hz to 400Hz) | ||||
Range | Resolution | Accuracy ±(%rdg+dgts) | Sensitivity | Overload Protection |
99.99A | 0.01A | ±(1% + 30) | 0.20 µA | 500V DC or AC rms |
999.9A | 0.1A | 2.0µA |
AC Voltage (50Hz to 400Hz) : TRMS | ||||
Range | Resolution | Accuracy ±(%rdg+dgts) | Sensitivity | Overload Protection |
999.9mV | 0.1mV | ±(1% + 30) (50, 60Hz ±(2% + 30) (40-400Hz | 2.0mV | 600V |
9.999V | 0.001V | 0.020V | ||
99.99V | 0.01V | 0.20V | ||
600.0V | 0.1V | 2V | ||
Input Impedance : 3MV |