Item(s) Added To Your Bag
Metravi 107F Digital Clamp On Power Meter
Metravi 107F Digital Clamp On Power Meter
10000 counts Digital Clamp-on Power Meter compatible with 3000A Flexible Clamp (optional accessory), AC/DC Voltage and AC/DC Current Auto Detection, NCV, Jaw Dia 42mm, KW, PF, THD up to 25th Harmonics. Automatically detects AC, DC and AC+DC of Ampere and Voltage function with AC+DC True RMS, and automatic selection of Resistance, Continuity and Diode. It has an active backlit display that turns ON at the touch of the button or rotation of knob. It also automatically goes off to save battery life. Comes with innovative torch light & live voltage sensing, Innovatively-designed Navigator, Extra temperature feature, Provides advanced Power features, Phase ratation, Total Harmonics Distrotion and even Harmonics 1 to 25th with easy-to-use interface.
Request Callback
Order In Bulk
Generate Quote
100% ORIGINAL Products
SECURE Payments
₹ 27,080.00
(GST inclusive price) i₹36,450.00
( - 26% OFF )
Description
What's in the box?
|
General Specification | |
Display count | 10000 |
Measuring rate | 3 times / sec. |
Over-range display | “OL” or “-OL” |
Auto Power-Off | Approx. 15 minutes |
Power requirement | 9V battery |
Battery life | ALKALINE 9V 50 hours (without Backlight) |
Dimensions | 87.5mm(W) x 257mm(L) x 50.5mm(D) |
Weight | approx. 470g (with battery) |
Electrical Specification | ||
Voltage | ||
Function | Range | Accuracy |
DCV | 99.99V | ± (0.7% + 2dgt) |
999.9V | ||
ACV | 99.99V | ± (1.0% + 5dgt) 50 ~ 500Hz |
999.9V | ||
HFR ACV | 99.99V | 50 ~ 60Hz ± (1% + 5dgt) >60 ~ 400Hz ± (5% + 5dgt) |
ACV |
Current | ||
Function | Range | Accuracy |
DCA | 99.99A | ± (1.5% + 0.2A) |
999.9A | ± (1.5% + 5dgt) | |
ACA | 0.10A ~ 99.99A | 50 ~ 60Hz ± (1.5% + 5dgt) >60 ~ 400Hz ± (2% + 5dgt) |
999.9A | ||
HFR ACA | 99.99V | 50 ~ 60Hz ± (1.5% + 5dgt) >60 ~ 400Hz ± (5% + 5dgt) |
ACV |
Peak Hold : Peak MAX / Peak MIN | ||
Function | Range | Accuracy |
ACV | 140.0V | ± (3.0% + 15dgt) |
1400V | ||
ACV | 140.0A | ± (3.0% + 15dgt) |
1400A |
Frequency | ||
Function | Range | Accuracy |
Frequency | 20.00 ~ 99.99Hz | ± (0.5% + 3dgt) |
20.0 ~ 999.9Hz | ||
0.020 ~ 9.999KHz |
Total Harmonic Distortion | ||
Function | Range | Accuracy |
ACA /ACV | 99.9% | ± (3.0% + 10dgt) |
Harmonic distortion measurement | ||
Harmonic order | Range | Accuracy |
H01 ~ H12 | 99.9% | ± (5% + 10dgt) |
H13 ~ H25 | ± (10% + 10dgt) |
Inrush Current | ||
Function | Range | Accuracy |
ACA | 99.99A | ± (2.5% + 0.2A) |
999.9A | ± (2.5% + 5dgt) |
Active Power : Watt (DC/AC) | ||
Function | Range | Accuracy |
ACW / DCW | 9.999 kW | A, error×V, reading+ V, error×A, reading |
99.99 kW | ||
999.9kW |
Power Factor | ||
Function | Range | Accuracy |
PF | 1.00 | ±5dgt |
Resistance & Continuity & Diode | ||
Function | Range | Accuracy |
Resistance | 999.9 Ω | ± (1.0% + 5dgt) |
9.999 kΩ | ± (1.0% + 3dgt) | |
99.99 kΩ | ||
Continuity | 999.9 Ω | ± (1.0% + 5dgt) |
Diode | 0.40~ 0.80V | ± 0.1V |
Capacitance | ||
Function | Range | Accuracy |
Capacitance | 3.999 μF | ± (1.9% + 8dgt) |
39.99 μF | ||
399.9 μF | ||
3999 μF |
Flex AC Current (voltage input) | ||
Function | Range(1mV/1A) | Accuracy * |
ACA | 300.0A/3000A | 1%+5dgt (50~500Hz) |
HFR ACA | 300.0A/3000A | 1%+5dgt(50~60Hz) 5%+5dgt(61~400Hz) |
Peak | 420.0A/4200A | 3%+80dgt(50~500Hz) |
INRUSH | 300.0A/3000A | 2%+10dgt(50/60Hz) |
Frequency | 99.99Hz/999.9Hz | 0.5%+3dgt(<500Hz) |
THD | 99.9% | 5%+10dgt |
Harm H01-H12 | 99.9% | 5%+10dgt |
Temperature | ||
Function | Range(1mV/1A) | Accuracy * |
°C | -50 °C ~ 99.9 °C | ± (1% + 2°C) |
100 °C ~ 399.9 °C 400 °C ~ 1000 °C | ± (1% + 1°C) | |
°F | -58 °F ~ 211.9 °F | ± (1% + 4°F) |
212.0 °F ~ 751.9 °F 752 °F ~ 1832 °F | ± (1% + 2°F) |