Description
What's in the box?
|
| Power | Two 1.5V alkaline batteries (LR6) |
| Power consumption | About 70m/3V |
| Maximum allowed voltage | 30V (within terminals or between terminal and earth ground) |
| Operation temperature range | 0°C ~ 50°C |
| Operation humidity range | ≤ 80%RH |
| Storage temperature range | ≤ - 10°C ~ 55°C |
| Storage humidity range | ≤ 90%RH |
| Temperature coefficient | 0.1 × (dedicated accuracy) %/ºC (5ºC ~ 18ºC , 28ºC ~ 40ºC) |
| Measurement | 180 (L) × 90 (W) ×47 (D) mm (with protector) |
| Weight | About 500g |
| Safety | Complies with IEC1010 (safety standard issued by International Electrician Committee) |
| Output function | Range | Output range | Resolution | Accuracy | Illustration | |
| Simulate resistance OHM | 400Ω | 0.0 ~ 400.0Ω | 0.1Ω | 0.05%+2 | Incentive current is set as: ± 0.5 ~ ± 3mA When the incentive current is set as ±0.1 ~ 0.5mA, add an extra 0.1Ω to additional error. The accuracy does not include lead resistance | |
| 4000Ω | 0 ~ 4000Ω | 1Ω | 0.05%+2 | Incentive current is set as ± 0.05 ~ ± 0.3mA The accuracy does not include lead resistance | ||
| Thermal resistance RTD | Cu10 | -10°C ~ 250°C | 0.1°C | 0.05% + 6 | Incentive current is set as ±0.5 ~ ± 3mA When the incentive current is set as ±0.1 ~ 0.5mA, add an extra 0.5°C to additional error. | Employs Pt (385) standard temperature The accuracy does not include lead resistance |
| Cu50 | -50.0°C ~ 150.0°C | Incentive current is set as ± 0.05 ~ ±0.3mA | ||||
| Pt10 385 | -200.0°C ~ 850.0°C | |||||
| Pt100 385 | -200.0°C ~ 850.0°C | |||||
| Pt200 385 | -200°C ~ 630°C | |||||
| Pt500 385 | -200°C ~ 630°C | |||||
| Pt1000 385 | -200.0°C ~ 630.0°C | |||||
| Resistance OHM | 500Ω | 0.0 ~ 500.0Ω | 0.1Ω | 0.05% + 2 | Measurement current : about 1mA Open circuit voltage : about 2.5V The accuracy does not include lead resistance | |
| 5000Ω | 0 ~ 5000Ω | 1Ω | 0.05% + 2 | Measurement current : about 1mA Open circuit voltage : about 2.5V The accuracy does not include lead resistance | ||
| Thermal resistance RTD | Cu10 | -10°C ~ 250°C | 0.1°C | 0.05% + 0.6ºC | The incentive current is set as : ±0. 5~ ±3mA When the incentive current is set as ±0.1~ 0.5mA, add an extra 0.5°C to additional error. | |
| Cu50 | -50.0°C ~ 150.0°C | |||||
| Pt10 385 | -200.0°C ~ 850.0°C | |||||
| Pt100 385 | -200.0°C ~ 850.0°C | Incentive current is set as ± 0.05 ~ ±0.3mA | ||||
| Pt200 385 | -200°C ~ 630°C | |||||
| Pt500 385 | -200°C ~ 630°C | |||||
| Pt1000 385 | -200.0°C ~ 630.0°C | |||||