Description

Key Features

  • This is a portable testing kit in one unit, suitable for testing protective relay, over current relay, earth fault relay, protective device, circuit breaker, tripping coils etc.
  • The set is designed for both laboratory and field use.
  • INPUT : 230 Volts, single phase, 50Hz. AC.
  • OUTPUTS :    : Current Output:  0- 1Amp. At  4/10Volts. / 0- 2Amp. At  4/10 Volts. / 0- 5 Amps. At 4/10 Volts. / 0- 10 Amps. At 4/10 Volts. / 0- 20 Amps.at
  • 4/10Volts. / 0- 50 Amps. At 4Volts. / 0-100 Amps. At 4 volts. / 0-200 Amps At 4Volts.
  • Current output is continuously variable and the output is taken out through a multi-range C.T. The secondary is connected to an ammeter scaled in 0 to 100%
  • AC Voltage Output: Continuously variable 0 -230V AC. Capacity- 460VA(Max).
  • Fixed AC voltage 50V &110V.
  • Time Measurement: 0-9.999Secs. & 0-99.99Secs. in two ranges. 
  • Accuracy :  1%

 

What's in the box?

  • Relay Test Set

Rating & Reviews

4.5
(Based On 10 Reviews)

Rating

0

0

0

0

0
Review Image

Product Specifications

Technical Specification
INPUT230 Volts, single phase, 50Hz. AC.
OUTPUTS1) Current Output:
a) 0-1Amp. At 4/10Volts.
b) 0-2Amp. At 4/10 Volts.
c) 0-5 Amps. At 4/10 Volts.
d) 0-10 Amps. At 4/10 Volts.
e) 0-20 Amps.at 4/10 Volts.
f) 0-50 Amps. At 4Volts.
g) 0-100 Amps. At 4 volts.
h) 0-200 Amps At 4Volts.
Current output is continuously variable and the output is taken out through a multi range C.T. The secondary is connected to an ammeter scaled in 0 to 100%
2) AC Voltage OutputContinuously variable 0-230V AC. Capacity- 460VA(Max).
3) Fixd AC voltage50V &110V
4) Time Measurement0-9.999Secs. & 0-99.99Secs. in two ranges. 1%
Accuracy
CURRENT CIRCUIT
0-9.999Secs. & 0-99.99Secs. in two ranges. 1%
Loading transformerDouble winding loading transformer of suitable burden is provided corresponding to current output specified
Measuring CTMulti ratio wound primary current transformer
Ratio Variable auto transformer1-2-5-10-20-50-100-200A/5A.
For smooth variation of current output at various ranges selected.
Metering
Digital meter. Basic Range - 0 to 5A AC. Scaled in 0 to 100% for all
VOLTAGE CIRCUITOne AC Voltmeter is provided for measuring the variable output AC voltage.
Timer circuit
Ranges
Dual range digital time interval meter
i) 0-9.999 Sec.
ii) 0-99.99Sec. in two switchable ranges.

Rating & Reviews

4.5
(Based On 10 Reviews)

Rating

0

0

0

0

0
Review Image