Metravi RNT-33 Relay Test Set

Click To Zoom

Metravi RNT-33 Relay Test Set

Metravi RNT-33 Relay Test Set

(Based On 10 Reviews)

METRAVI" Relay Test Set, RNT-33 is suitable for testing distance relays. However other relays like over current, over voltage, under voltage, earth fault and relays having directional elements can also be tested by this relay test set. The set is in two units.

Request Callback

Order In Bulk

Generate Quote

₹ 3,62,813.00

(GST inclusive price) i
  • Base Value: ₹ 307468.6
  • GST: (18) % ₹ 55344.4
  • Total Value ₹ 362813

₹3,62,813.00

( - 0% OFF )

Need Help ?

Our Client Care Managers Are On Call 24/7 To Answer Your Question.

Description

Key Features

  • Fault phase voltage adjustable at 80%, 90%, 100%& 110%
  • Fault current adjustable between 0 to 100%
  • Phase angle adjustment & measurement 0° to 360° in current ckt.
  • Digital time interval meter.
  • Voltage & current indications by digital meters

 

What's in the box?

  • Relay Test Set

Rating & Reviews

4.5
(Based On 10 Reviews)

Rating

0

0

0

0

0

Product Specifications

Technical Specification
Input Voltage Output (s)415V ± 10%, 3phase, 4 wire 50HZ AC.
[a] Test Current0 to 1,5,10,25A, 50A having 0 to 100% regulation in each tap & each phase.
Rated maximum burden250 VA.
Duty Cycle: i)continuous upto 10A. ii) 25A & 50A outputs are rated for intermittent duty cycle i.e. 5mins "ON", 10mins" OFF ".
[b] Test Voltages AC Voltage source110 volts, phase to phase, 63.5 volts phase to neutral, 3phase 50 HZ AC. Only one phase voltage (R-Phase) can be adjusted 0-220V by using one voltage rgulator that can be selectable
Rated maximum burden50VA/ phase
Fixed DC voltage sourceIsolated fixed 30V/110V/220V DC of 100VA, with out metering
[c] Phase Angle Variation0 to 360° in current ckt.
[d] Time Measurement0-9.999 secs.& 0-99.99secs in two selectable ranges
CURRENT CIRCUIT Loading TransformerDouble winding loading tran-sformer of suitable burden toprovide corresponding curre-nt output specified before.
Measuring C. TMulti ratio wound primary current transformer.
Ratio1-5-10-25-50/1A with current range selectable rotary switch
Variable Auto-Transformer[1 no for each phase] For smooth variation of current output at various ranges selected.
Tripping circuitThe current output will be cutoff incase of any overload or even if the relay under test actuates
MeteringC.T. operated ammeter [1no for each phase
Range0 to 1A AC.
Scaled0 to 100% for all the selected current ranges.
Accuracy±1%
Resolution0.1%
VOLTAGE CIRCUIT
AC VOLTAGE CIRCUIT
3 phase autotransformer for rated output voltage selection 80%, 90%, 100% & 110% of 110Volts by selection switch
METERINGVoltmeter with phase selector switch.
Range0 to 300 V.
Accuracy± 1%
Resolution1V.
DC VOLTAGE CIRCUITDouble wound multitap isola-ted
transformer is provided for fixed DC voltages sources 30V/110V/220V are selected one at a time by selector switch.
PHASE SHIFTER CIRCUITStatic Type Phase Shifting Transformer
Primary voltage415V, 3phase, 50HZ. AC.
Secondary voltage415 V, 3phase, 50HZ. AC. 0 to 360° phase angle variation by coarse and fine control. Coarse control will be in steps of 60° while fine control will be of ± 30°
Capacity50VA per phase.
METERING
Phase Angle Meter
0-360°
Resolution1%. There will be provision for phase selection by selector switch.
BUILT-IN-TYPE DIGITAL TIMER Measuring RangeResolution
9.999secs.0.001sec.
99.99secs.0.01sec.
DisplaySeven segment LED.
Accuracy±1%.
Terminals to relay contacts.
Reset push button.Selector for NO & NC contact.
When the relay under test actuates, there will be automatic tripping of the output current circuit.
Unit having current source, voltage source & measuring facilities.Current circuit, AC & DC voltage circuits, protective circuit, contactors, measuring circuits etc. will all be housed within sturdy M.S. cabinet. Also meters, terminals, indicators, regulator knobs, timer display etc.will be fitted on the horizontal panel of the same cabinet which can be approached by opening the top hinged lid. Wheels will be provided for easy movement.
Phase shifter unitStatic type phase shifting transformer will be housed within this M.S. unit.
Input output connection socket, phase shifting "Coarse" & "Fine" knobs are fitted on the horizontal plane of the sturdy M.S. cabinet which can be approached by opening the top hinged lid.
INTER CONNECTION CABLENecessary cables of 1 meter length along with plug will be provided for inter connect- ion between two units
MAINS INPUT CABLEFour core cable of 5 meters length will be provided.
All the meters will be digital type. Operational manual, Schematic Circuit Diagram, Works Test Report, Warranty Certificate will be supplied along with the set.
The set is in two unitsi) Current source, voltage source & measuring facilities.
ii) Phase shifter unit.