Item(s) Added To Your Bag

Metravi 6060 Analogue Multimeter

Click To Zoom

Metravi 6060 Analogue Multimeter

Metravi 6060 Analogue Multimeter

(Based On 10 Reviews)

Measures AC / DC Voltage up to 2500V, AC/DC Current up to 10A, Resistance up to 10K Ohms, Diode and Continuity test facility.

Request Callback

Order In Bulk

Generate Quote

100% ORIGINAL Products
100% ORIGINAL Products Details

100% ORIGINAL Products

SECURE Payments
SECURE Payments Details

SECURE Payments

₹ 14,543.00

(GST inclusive price) i
  • Base Value: ₹ 12324.6
  • GST: (18) % ₹ 2218.4
  • Total Value ₹ 14543

₹19,575.00

( - 26% OFF )

Need Help ?

Our Client Care Managers Are On Call 24/7 To Answer Your Question.

Description

Key Features

  • Temperature: 23°C ±2K
  • Humidity: 45%RH ±5%
  • Position: horizontal ±2°
  • DC Voltage :  0 – 2.5V/10V/25V/100V/250V/500V/1000V/2500V
  • Accuracy :  ± 1.5%
  • AC Voltage :  0 – 2.5V/10V/25V/100V/250V/500V/1000V/2500V
  • Accuracy :  ± 2.5%
  • DC Current :  0 – 1mA/10mA/50mA/100mA/250mA/1000mA/10A
  • Accuracy :  ± 1.5%
  • AC Current :  100mA/1000mA/2500mA/10A
  • Accuracy:  2.5%
  • Resistance :  0 §Ù to 10K§Ù
  • Accuracy :  ± 10%

 

What's in the box?

  • Metravi 6060 Analogue Multimeter

Rating & Reviews

4.5
(Based On 10 Reviews)

Rating

0

0

0

0

0
Review Image

Product Specifications

General Specification

Dimensions and weight

165×105×50mm and 670g

Power supply

1.5V×3 battery (AA)

Maximum climatic conditions

Temperature use -10°C to +50°C; storage -30°C to +70°C
Relative humidity use ≤80% HR
Altitude use <2000m

Compliance with international standards

Electrical safety (EN 61010-1:2001) CEI 1010-1 EN61010 NF-C 42020 VDE 0411
Double insulation:Pollution level: 2
Installation category: III according to CEI 664
Allocated voltage: 600V

Electromagnetic compatibility

Emission (EN 61326-1:2006)
Immunity (EN 61326-1:2006)

 

Technical Specification

DC VOLTAGE

VDC

2.5V

10V

25V

100V

250V

500V

1000V

2500V

Range(indication)

50

100

50

100

50

50

100

50

Reading coefficient

×0.05

×0.1

x1

x1

x5

×10

×10

×50

Internal resistance

50ΚΩ

200ΚΩ

2ΜΩ

2ΜΩ

5ΜΩ

4,5ΜΩ

9ΜΩ

22.5ΜΩ

Admissible overload

240V

420V

600V

600V

600V

600V

1200V

2500V

 

AC VOLTAGE

VDC

2.5V

10V

25V

100V

250V

1000V

2500

Range(indication)

2.5

100

50

100

50

100

50

Reading coefficient

x1

x0.1

×0.5

x1

x5

×10

×50

Internal resistance

22.5ΚΩ

90ΚΩ

225ΚΩ

900ΚΩ

2.25ΜΩ

9ΜΩ

22.5ΜΩ

Admissible overload

240V

320V

470V

600V

600V

1200V

2500V

 

DC CURRENT

ADC

Scale (indication)

Reading coefficient

Voltage drop at inputs

Accuracy

Protection

1mA

100

×0.01

480mV

1.5%

3A/500V

10mA

100

×0.1

480mV

50mA

50

x1

480mV

100mA

100

x1

480mV

250mA

50

x5

480mV

1000mA

100

×10

480mV

10A

100

×0.1

480mV

10A/500V

 

AAC

100mA

1000mA

2500mA

10A

Scale(indication)

100

100

50

100

Reading coefficient

x1

x10

x50

×0.1

Voltage drop at inputs

1.2V

1.2V

1.2V

100mV

Accuracy

2.5%

Protection

3A/500V

10A/500V

Rating & Reviews

4.5
(Based On 10 Reviews)

Rating

0

0

0

0

0
Review Image